← Back to the X22
Technical Data
X22 – Technical Data
Complete technical overview of the X22 across all tool interfaces and cooling types –
with weight, connections and pressures taken directly from the X22 operating manual.
Which values apply exactly depends on the configuration – you put this together in the
configurator.
Overview
| Series | X22 – compact high-frequency motor spindle (HF/CNC milling spindle) |
| Power | 1.5 / 2.2 / 3.0 / 4.0 kW (S1 continuous duty) |
| Speed | up to 65,000 min⁻¹ (depending on tool interface) |
| Motor type | Asynchronous (1.5 / 2.2 / 3.0 kW), synchronous (4.0 kW) |
| Voltage | 230 V / 400 V |
| Cooling | Air cooling or liquid cooling |
| Tool interfaces | ER20, ER25, HSK-C25, HSK-C32, HSK-E25, HSK-E32, SK20, DTC |
| Weight | 4.6 – 6.3 kg (depending on version) |
| Dimensions (W × D) | 88 × 91 mm · length 220 – 335 mm (depending on version) |
| Protection class | IP54 (liquid) / IP20 (air) – optionally up to IP65 |
| Manufacture | Development & manufacture in Weiterstadt, Germany (made in Germany) |
Base configurations & weights
| Interface | Tool change | Cooling type | Weight | Part no. |
| ER20 | manual (MTC) | Liquid | 4.6 kg | XP001 |
| ER20 | manual (MTC) | Air | 4.9 kg | XP002 |
| ER25 | manual (MTC) | Liquid | 4.6 kg | XP003 |
| ER25 | manual (MTC) | Air | 4.9 kg | XP004 |
| HSK-C25 | semi-auto (QTC) | Liquid | 4.8 kg | XP021 |
| HSK-C25 | semi-auto (QTC) | Air | 4.9 kg | XP023 |
| HSK-C32 | semi-auto (QTC) | Liquid | 4.8 kg | XP022 |
| HSK-C32 | semi-auto (QTC) | Air | 4.9 kg | XP024 |
| HSK-E25 | automatic (ATC) | Liquid | 5.9 kg | XP005 |
| HSK-E25 | automatic (ATC) | Air | 6.2 kg | XP006 |
| HSK-E32 | automatic (ATC) | Liquid | 5.9 kg | XP168 |
| HSK-E32 | automatic (ATC) | Air | 6.2 kg | XP169 |
| SK20 | automatic (ATC) | Liquid | 5.8 kg | XP007 |
| SK20 | automatic (ATC) | Air | 6.3 kg | XP008 |
| DTC | direct shank (DTC) | Liquid | 5.8 kg | XP174 |
| DTC | direct shank (DTC) | Air | 6.3 kg | XP175 |
16 base configurations; numerous additional options (motor, speed, bearings, sensors) are freely selectable.
Motor variants
| Power (S1 / S6) | Voltage | Number of poles | Current (S1) | Motor type |
| 1.5 / 1.8 kW | 230 V | 2-/4-pole | 5.5 A | Asynchronous |
| 1.5 / 1.8 kW | 400 V | 2-/4-pole | 3.1 A | Asynchronous |
| 2.2 / 2.5 kW | 230 V | 2-/4-pole | 8.0 A | Asynchronous |
| 2.2 / 2.5 kW | 400 V | 2-/4-pole | 4.6 A | Asynchronous |
| 3.0 / 3.3 kW | 230 V | 2-/4-pole | 10.9 A | Asynchronous |
| 3.0 / 3.3 kW | 400 V | 2-/4-pole | 6.3 A | Asynchronous |
| 4.0 / 5.8 kW | 400 V | 4-pole | 7.7 A | Synchronous |
S1 = continuous duty, S6 = intermittent duty. Corner frequency 400 Hz (synchronous 4.0 kW: 800 Hz). Optionally with potted stator (included with 3.0 & 4.0 kW).
Tool interfaces
| Interface | Design | Tool change | Clamping/shank range | max. speed |
| ER20 | Collet | manual | 1 – 13 mm | 65,000 min⁻¹ |
| ER25 | Collet | manual | 1 – 16 mm | 45,000 min⁻¹ |
| HSK-C25 | Hollow shank taper | semi-automatic | – | 65,000 min⁻¹ |
| HSK-C32 | Hollow shank taper | semi-automatic | – | 45,000 min⁻¹ |
| HSK-E25 | Hollow shank taper | automatic | – | 65,000 min⁻¹ |
| HSK-E32 | Hollow shank taper | automatic | – | 45,000 min⁻¹ |
| SK20 | Steep taper | automatic | – | 45,000 min⁻¹ |
| DTC | Direct shank change | automatic | 6 mm (opt. 3–10 mm) | 65,000 min⁻¹ |
HSK-E25/HSK-E32 in accordance with DIN 69863. With DTC, tools can be clamped directly on the shank (base configuration 6 mm; optionally 3 mm, 1/8″, 4, 5, 8, 10 mm). Maximum speeds with front hybrid bearing and high-power fan.
Liquid cooling
| Coolant | 30 % glycol-water mixture (e.g. SPINOGY / Xcool coolant) |
| Supply temperature | min. 20 °C |
| Flow rate | min. 1.5 l/min |
| Return temperature | max. 40 °C |
| Sound pressure level (with Xcool) | 52 dB(A) at standstill · 64 dB(A) at 30,000 min⁻¹ |
| Protection class | IP54 (optionally IP65) |
Do not use pure or distilled water – always add corrosion protection. Housing temperature max. 45 °C.
Air cooling (external ventilation)
| Parameter | up to 35,000 min⁻¹ | from 40,000 min⁻¹ or ≥ 3.0 kW |
| Voltage type | 24 V DC | 24 V DC |
| Rated current | 0.46 A | 1.58 A |
| Power consumption | 11 W | 38 W |
| Fan speed | 8,400 min⁻¹ | 14,000 min⁻¹ |
| Sound pressure level | 62 dB(A) / 66 dB(A)* | 71 dB(A) |
| Fan grille | Performance | High-Performance |
* at standstill / at 30,000 min⁻¹. Protection class IP20 (optionally IP50 with filter mat). The fan intake area must always be kept clear.
Connections
| Motor connection | 9-pin, straight or angled |
| Sensor connection | 17-pin, straight or angled (for MTC / QTC from the second sensor onwards) |
| Coolant connection | 2 × push-in fitting Ø 8 mm (Win inlet / Wout outlet) – liquid cooling only |
| Pneumatic connection | 3 × push-in fitting Ø 6 mm (LD / PR / KBL) – automatic tool change only |
Pneumatics & pressures
| Port | Function | Pressure level | Hose |
| P1 | Release pressure (release tool) | 6 – 10 bar | Ø 6 mm |
| P2 | Taper blow-off air (clean taper) | 1.5 – 2 bar | Ø 6 mm |
| P3 | Pneum. return (clamp tool) | min. 3 bar | Ø 6 mm |
Recommended pneumatic valve nominal flow ≥ 150 l/min. Switch taper blow-off air with a time delay of approx. 0.7 s after the release pressure. With the Xcontrol-P this wiring is already prepared.
Tightening torques
| Element | Range | Tightening torque |
| ER20 (mini clamping nut) | 1.0 mm | 16 Nm |
| ER20 (mini clamping nut) | 1.5 – 13.0 mm | 28 Nm |
| ER25 (mini clamping nut) | 1.0 – 3.5 mm | 24 Nm |
| ER25 (mini clamping nut) | 4.0 – 17.0 mm | 32 Nm |
| HSK-C tool holder (QTC) | – | 3 Nm |
| SK20 pull stud | – | 15 Nm |
| Mounting screws (installation) | 4 × M6 | 8 – 10 Nm |
Bearings
| Front bearing | Steel or hybrid bearing |
| Rear bearing | Steel or hybrid bearing |
| Front hybrid bearing | included from 40,000 min⁻¹ (with high-power fan) |
| Lubrication | lifetime grease-lubricated, maintenance-free (re-greasing no earlier than after 2,000 operating hours) |
Sensors
| Temperature sensor (standard) | PTC, 130 °C, on the motor winding head |
| Temperature (optional) | PTC 70 °C or PT100 on front/rear bearing (PT100: −70 … +500 °C, class B) |
| Speed sensor | inductive (monitoring 2 pulses/rev, control 32 pulses/rev) or encoder analogue/digital – speed, direction of rotation, absolute position |
| Clamping position sensor | 2 × inductive (clamped with / without tool) – automatic tool change |
| Piston position sensor | inductive – automatic tool change & DTC |
Sealing & protection
| Shaft seal | 5-stage labyrinth seal at the front bearing point – thus saving sealing air |
| Protection class | IP54 (liquid) / IP20 (air) – optionally IP50 (filter mat) or IP65 (liquid) |
| Statutory warranty | 24 months |
| Warranty | 3 years – extendable up to 6 years |
Subject to technical changes and errors; the respective configuration is decisive.