xcontrol-e Enquire
← Back to the Xcontrol-E
Technical Data

Xcontrol-E – Technical Data

All technical data of the Xcontrol-E – the electrical plug-&-play controller in the control cabinet for SPINOGY motor spindles. It contains all components for operating a spindle and is freely configurable.

Overview

ProductXcontrol-E – electrical control (control cabinet, plug & play)
Power classes1.5 / 2.2 / 3.0 kW · 4.0 / 5.5 kW
Frequency inverterSVC or HF, factory-programmed
Emergency stop circuit2-pole with switch-off delay and manual reset
Inputs/outputs (customer-side)12 inputs / 19 outputs
Control cabinet housingEMC-compliant, protection class IP20
Compatible withall SPINOGY motor spindles (X22 & X30, all configurations)
ManufactureDevelopment & manufacture in Weiterstadt, Germany (made in Germany)

Sizes

Parameter1.5 / 2.2 / 3.0 kW4.0 / 5.5 kW
Mains connection230 V (1-phase)400 V (3-phase)
Frequency inverter (base config.)2.2 kW SVC 230 V4.0 kW SVC 400 V
Braking resistor70 Ω, 600 W / 10 s, 2 % duty cycle120 Ω, 600 W / 10 s, 2 % duty cycle
Weight16 kg33 kg
Dimensions (W × H × D)400 × 500 × 210 mm600 × 600 × 250 mm
Protection classIP20IP20

For each size there are variants for liquid- or air-cooled spindles, manual/semi-automatic or automatic – each also available as a DIY version.

Frequency inverter (configurable)

PowerVoltageRated output currentBraking resistor
1.5 kW230 V (1-ph.)8.0 A70 Ω
1.5 kW400 V (3-ph.)4.8 A200 Ω
2.2 kW230 V (1-ph.)11.0 A70 Ω
2.2 kW400 V (3-ph.)5.5 A200 Ω
3.0 kW400 V (3-ph.)7.2 A120 Ω
4.0 kW400 V (3-ph.)9.2 A120 Ω
5.5 kW400 V (3-ph.)14.8 A75 Ω

Available as SVC or HF in each case. Braking resistors 600 W / 10 s, 2 % duty cycle. Input voltage single-phase 200–240 V or three-phase 380–480 V (50/60 Hz).

Components

Power supply unit24 V – 30 W (liquid-cooled spindle) or 60 W (air-cooled spindle); 1.3 A / 2.5 A
Safety relay24 V DC, 2 NO contacts direct + 2 NO contacts with switch-off delay (max. 30 s)
Circuit breakerB16 A – 1-pole (230 V) or 3-pole (400 V)
Main switchlatching, lockable in the 0 position (20 A / 32 A)
Emergency stop switch2× NC contact, twist-to-release
Coupling relay24 V DC, 2 changeover contacts, max. 8 A

Connections & cable lengths

Motor connection (orange)Standard 5 m (optionally 2 – 20 m)
Sensor connection (green)Standard 5 m (for automatic tool change)
PE protective earth (green/yellow)Standard 5 m (2 – 8 m)
Mains connectionStandard 5 m; earthed plug (230 V) or CEE plug (400 V)
Further interfaceIntegration of Xcontrol-P and Xcool into the safety circuit

Communication interfaces (optional)

OptionsRJ45 · USB · Profibus · Profinet
Inverter programmingfactory-programmed; customer-specific configurations on request

Installation & warranty

Mountingvertical, connection cables facing downwards; > 100 mm clearance (keep fan clear)
Statutory warranty24 months

Subject to technical changes and errors; the respective configuration is decisive.