← Back to the Xcontrol-E
Technical Data
Xcontrol-E – Technical Data
All technical data of the Xcontrol-E – the electrical plug-&-play controller in the control cabinet for SPINOGY motor spindles. It contains all components for operating a spindle and is freely configurable.
Overview
| Product | Xcontrol-E – electrical control (control cabinet, plug & play) |
|---|---|
| Power classes | 1.5 / 2.2 / 3.0 kW · 4.0 / 5.5 kW |
| Frequency inverter | SVC or HF, factory-programmed |
| Emergency stop circuit | 2-pole with switch-off delay and manual reset |
| Inputs/outputs (customer-side) | 12 inputs / 19 outputs |
| Control cabinet housing | EMC-compliant, protection class IP20 |
| Compatible with | all SPINOGY motor spindles (X22 & X30, all configurations) |
| Manufacture | Development & manufacture in Weiterstadt, Germany (made in Germany) |
Sizes
| Parameter | 1.5 / 2.2 / 3.0 kW | 4.0 / 5.5 kW |
|---|---|---|
| Mains connection | 230 V (1-phase) | 400 V (3-phase) |
| Frequency inverter (base config.) | 2.2 kW SVC 230 V | 4.0 kW SVC 400 V |
| Braking resistor | 70 Ω, 600 W / 10 s, 2 % duty cycle | 120 Ω, 600 W / 10 s, 2 % duty cycle |
| Weight | 16 kg | 33 kg |
| Dimensions (W × H × D) | 400 × 500 × 210 mm | 600 × 600 × 250 mm |
| Protection class | IP20 | IP20 |
For each size there are variants for liquid- or air-cooled spindles, manual/semi-automatic or automatic – each also available as a DIY version.
Frequency inverter (configurable)
| Power | Voltage | Rated output current | Braking resistor |
|---|---|---|---|
| 1.5 kW | 230 V (1-ph.) | 8.0 A | 70 Ω |
| 1.5 kW | 400 V (3-ph.) | 4.8 A | 200 Ω |
| 2.2 kW | 230 V (1-ph.) | 11.0 A | 70 Ω |
| 2.2 kW | 400 V (3-ph.) | 5.5 A | 200 Ω |
| 3.0 kW | 400 V (3-ph.) | 7.2 A | 120 Ω |
| 4.0 kW | 400 V (3-ph.) | 9.2 A | 120 Ω |
| 5.5 kW | 400 V (3-ph.) | 14.8 A | 75 Ω |
Available as SVC or HF in each case. Braking resistors 600 W / 10 s, 2 % duty cycle. Input voltage single-phase 200–240 V or three-phase 380–480 V (50/60 Hz).
Components
| Power supply unit | 24 V – 30 W (liquid-cooled spindle) or 60 W (air-cooled spindle); 1.3 A / 2.5 A |
|---|---|
| Safety relay | 24 V DC, 2 NO contacts direct + 2 NO contacts with switch-off delay (max. 30 s) |
| Circuit breaker | B16 A – 1-pole (230 V) or 3-pole (400 V) |
| Main switch | latching, lockable in the 0 position (20 A / 32 A) |
| Emergency stop switch | 2× NC contact, twist-to-release |
| Coupling relay | 24 V DC, 2 changeover contacts, max. 8 A |
Connections & cable lengths
| Motor connection (orange) | Standard 5 m (optionally 2 – 20 m) |
|---|---|
| Sensor connection (green) | Standard 5 m (for automatic tool change) |
| PE protective earth (green/yellow) | Standard 5 m (2 – 8 m) |
| Mains connection | Standard 5 m; earthed plug (230 V) or CEE plug (400 V) |
| Further interface | Integration of Xcontrol-P and Xcool into the safety circuit |
Communication interfaces (optional)
| Options | RJ45 · USB · Profibus · Profinet |
|---|---|
| Inverter programming | factory-programmed; customer-specific configurations on request |
Installation & warranty
| Mounting | vertical, connection cables facing downwards; > 100 mm clearance (keep fan clear) |
|---|---|
| Statutory warranty | 24 months |
Subject to technical changes and errors; the respective configuration is decisive.