← Back to the Xcool
Technical Data
Xcool – Technical Data
All technical data of the Xcool cooling unit for liquid-cooled SPINOGY motor spindles – taken directly from the operating manual: cooling capacity, flow rate, tank capacity, dimensions, sensors and connections.
Overview
| Product | Xcool – cooling unit for SPINOGY motor spindles (liquid cooling) |
|---|---|
| Voltage | 230 V |
| Max. power consumption | 40 W |
| Max. cooling capacity | 600 W (at 20 °C) |
| Max. flow rate | 6.8 l/min |
| Max. delivery head | 10 m |
| Tank capacity | 3.5 l |
| Empty weight | 9.8 kg |
| Dimensions (W × H × D) | 470 × 206 × 310 mm |
| Protection class | IP20 |
| Sensors | Flow and temperature monitoring |
| Manufacture | Development & manufacture in Weiterstadt, Germany (made in Germany) |
Coolant
| Recommended | SPINOGY coolant |
|---|---|
| Alternative | 30 % glycol-water mixture |
| Important | no pure or distilled water – always add corrosion protection |
Pump
| Max. flow rate | 6.7 l/min |
|---|---|
| Max. delivery head | 10 m |
| Supply voltage | 24 V |
| Max. current | 1.1 A |
| Noise level | < 30 dB(A) at 1 m distance |
Fan
| Speed | 2,000 min⁻¹ |
|---|---|
| Air flow rate | 2,000 m³/h |
| Supply voltage | 24 V |
| Max. current | 1.1 A |
| Noise level | 31.5 dB(A) |
Sensors & monitoring
| Temperature sensor | measures the coolant return; switching threshold 45 °C (shown on the display) |
|---|---|
| Flow sensor | Continuously monitors the flow; switching threshold > 0.55 l/min |
| Alarm | when the temperature is exceeded or the flow falls below the threshold: red LED, warning signal and relay switching |
| Flow monitor | max. switching voltage 230 V · switching capacity 10 W · contact: NO |
Connections
| Coolant inlet (IN) | Push-in fitting Ø 8 mm hose → spindle Win |
|---|---|
| Coolant outlet (OUT) | Push-in fitting Ø 8 mm hose → spindle Wout |
| Mains connection | IEC appliance inlet with integrated fine-wire fuse (230 V) |
| Signal socket | Relay output for integration into the machine control (pin 1 common, pin 2 NO, pin 3 NC) |
Integration into the Xcontrol-E is possible – in the event of a temperature or flow fault, the emergency stop is triggered and the spindle is stopped.
Compatibility & installation
| Compatible with | all liquid-cooled SPINOGY motor spindles (X22 & X30); spindles from other manufacturers upon agreement |
|---|---|
| Minimum clearances | > 100 mm to the side and rear walls (keep the intake and outlet areas clear) |
| Filter mat | side fan grille with filter mat – clean regularly |
Warranty
| Statutory warranty | 24 months |
|---|
Subject to technical changes and errors; the respective configuration is decisive.